Scrubber Design Calculation Excel Hot
wet scrubber design calculation Excel sheet
To get a highly accurate , you must account for thermal effects, evaporation, and gas expansion when handling hot gas streams .
Evaporation % of recirc flow
Excel check: Add a cell that calculates . If > 3-5%, you need blowdown or a bigger pump. scrubber design calculation excel hot
- Error: The mist eliminator (cheVRon) is at the cold outlet. If you size it for the hot inlet velocity, the cold, dense gas will move too slowly, failing to coalesce droplets.
- Fix: Size the chevron using outlet ACFM.
The pressure drop ($\Delta P$) represents the energy used to accelerate the liquid droplets to the gas velocity. This calculation utilizes the Hesketh or Calvert correlation. wet scrubber design calculation Excel sheet To get
Target:
Keep pressure drop between 0.5 and 1.0 inches of water column per foot of packing. Excel Setup Tips for Engineers Error: The mist eliminator (cheVRon) is at the cold outlet
Leave a comment